A750E/F A761E Line Pressure
A750E A750F Line Pressure
Condition | D Position LPA (kgf/cm^2, PSI) | R Position KPA (kgf/cm^2, PSI) |
Idling |
363 to 423 kPa (3.7 to 4.3 kgf/cm^2, 53-61 PSI) |
484 to 564 kPa (4.9 to 5.8 kgf/cm^2, 70 to 82 PSI) |
Stall Test |
1282 to 1381 kPa (13.1 to 14.1 kgf/cm^2, 186 to 200 PSI) |
1218 to 1338 kPa (12.4 to 13.6 kgf/cm^2, 177 to 194 PSI) |
A761E Line Pressure
Condition | D Position LPA (kgf/cm^2, PSI) | R Position KPA (kgf/cm^2, PSI) |
Idling |
355 to 425 kPa (3.6 to 4.3 kgf/cm^2, 51-62 PSI) |
631 to 731 kPa (6.4 to 7.5 kgf/cm^2, 92 to 106 PSI) |
Stall Test |
1277 to 1387 kPa (13.0 to 14.1 kgf/cm^2, 185 to 201 PSI) |
1462 to 1670 kPa (14.9 to 17.0 kgf/cm^2, 212 to 242 PSI) |